Create your free account now! Sign up

I&R, Bonded Copper, HDSL, Prism installation Techs

Contract Employee


Colorado

Immediate need for I&R Techs (Bonded Copper) in Ft Collins CO, 60hr work weeks-(6 10's)

Starts

7/1/2016 to 11/14/2016

Pay

$20 to $29 DOE; HST3000 meter rentals included

Qualifications

Valid DL, 5+ years of relevant Telcom I&R exp, clear criminal record, Truck and Tools, Ladder rack

Other Requirements

Tools • 3M 710 Modular Splicing Rig • 3M MS2 Modular Splicing Rig • Battery/Electric Drill • Belt and Hand Tool Pouch • Blanket – Rubber Class II (Minimum 17KV) • Block/Tackle w/25 ft. Rope • Boot Safety Toe • Claw Hammer • Cleaning Supplies – Fiber Optic, Port End Face • Cleaver – Handheld One-Step or Equivalent (Ribbon Cleaver-Area Specific, Hot Jacket Stripper-Area Specific) • Climbing Apparatus (Safety Belt and Gaffs) (wood pole fall restriction

Job Description

•Prior HDSL/ Prism and or GPON installation exp is a must.

Analyze and troubleshoot basic technical problems or issues.
• Review and discuss service order requirements and equipment requests with customers, evaluating customers’ telecommunication needs and suggesting additional/alternative service as appropriate.
• Install, maintain/repair, and test residential/small business telecommunication service (POTS, Hicap circuits and HSI).
• Initiate or perform cable cuts, transfer projects, and/or load balance cuts, and issues necessary to prevent blocking.
• Run cross-connects.
• Review, interpret and work with information on trunk orders, facility orders, message trunk orders, network design orders and/or circuit layout orders.
• Routinely inspect all parts of the frame for breaks or loose equipment.
• Test and check equipment and/or assists other employees in testing and checking equipment.
• Maintain daily frame logs for work unit credit, and files service orders
• Connect, disconnect, remove, rearrange and maintain wires inside a central office.
• Connect wires and cables to terminals, and attaches/detaches various kinds of hardware to wires, cables, buildings, and poles.
• Use hand tools, power tools (air and electric), and specialty tools, including electric and electronic measuring devices (e.g., multi-meters, volt-ohm meters).
• Perform continuity and/or conformance testing.
• Read and interpret customer service orders, repair tickets, technical (i.e., mechanical, electrical, digital) drawings, maps, blueprints, diagrams, etc. from supervisor or other designated employees and performs specified work.
• Work with telecom color-coded wires and cables.
• Repair cut cable of all sizes.

additional tool list requirements...
• Clip, Hand Line Safety
• Cutter – Bolt 36 inch
• Cutter – Cable 36 inch
• Cutters – Cable (Handheld)
• Cutters – Fiber (Loose Buffer, Uni-tube, Micro-duct, Mini-duct and Conduit)
• Drill Bits – Various Sizes (Masonry, Steel and Wood)
• End Plate Cutter and Blade Kit
• End Plate Removal Tool
• Extension Cord – Outdoor Rated (Minimum 25 ft.)
• Fiber Assembly Tool (Ribbonizer Tool)
• Fish Tape – Fiberglass w/leader
• Flashlight/Work light (Portable Battery Type)
• Gloves – Disposable
• Gloves – Leather Work Type
• Gloves – Rubber (Class II) – Minimum 17 KV Gloves – Rubber Insulating (Class II) – Minimum 17 KV (shall include rubber glove, liner, and outer leather protector and carry bag).
• Hammer – Lineman
• Hand line Utility
• Hard Hat (ANSI Type I, Class E&G)
• Hook F/Manhole Cover
• Kit - First Aid
• Kit - Hantavirus
• Knife Cable w/Pouch
• Ladder Ext 28 ft. (Fiberglass) - minimum 300 pound rated Type 1A. Ladder use must not exceed weight of personnel, tools and equipment
• Ladder Step 6 ft. (Fiberglass) - minimum 300 pound rated Type 1A. Ladder use must not exceed weight of personnel, tools and equipment
• Lead Cable/Closure Entry Tools – Associated Lead Cable materials and safety supplies as required by Client EH&S Policy
• Non-Conductive Shovels (Spade and Trenching)
• Pica bond Connector Tool (AMP gun) for sealed paper/pulp applications ONLY
• Platform – Aerial (available as required)
• Pliers – Insulated (Various Types)
• Probe AMP Clamp on
• Pruner – Tree w/Fiber Glass Handle Extensions
• Punch Down Tool (66 Type Block Impact Tool)
• Punch Shield Bond
• Ribbon Splitter-Area Specific
• Safety Cones – 36” w/Dual Collars – Minimum of two cones
• Safety Glasses
• Safety Vest Class II
• Scissors Electrical (Snips)
• Screw Drivers – Insulated (Various Size and Type)
• Sling – Ladder Aerial - minimum 300 pound rated Type 1A. Ladder use must not exceed weight of personnel, tools and equipment
• Slitter Drop Wire (Flat Drop)
• Slitter- Fiber Buffer Tube
• Static Wrist Strap
• Strippers – Fiber, various (250 and 900 Micron)
• Tent – Aerial Messenger Mount
• Tent – Ground
• Tool – Fiber Mid-Span Access
• Tool – Glow Rod (Wall Rod)
• Tool Crimp (3M Brand Only Scotchlok)
• Tool Hand Presser 3M for 710 Mod
• Tool Wire Insertion 3M Mini Mod MS2 4051
• T25 Stapler w/Staples
• T25AC Stapler w/Staples (Cat 5E)
• T37AC Stapler w/Staples (Coax)
• Tool Wire Wrap/Unwrap 22/24 AWG
• Torque Wrench (Inch Pounds)
• Wire Stripper – 22-26 AWG
• Wrench Adjustable SGL 12 inch
• Wrench Terminal Can Wrench 3/8x7/16

6.2 Test Equipment
• Adapter Modular Test 4 Wire (Banjo)
• Adapter Bare Fiber
• Cable Locator – Minimum 3 watt with “A” earth frame. Must be Shield Fault and EMS locate capable.
• Client Approved/Comparable Equipment:
• Copper/xDSL/ Portable Test Set (including TDR and Far End Device, must be Wideband and Bonded Services capable for all Client xDSL profiles)
• Data Safe – Butt Set
• Fiber Fusion Welder (Core Alignment Single Fiber, Profile Alignment, Mass Fusion and Fuse on Connector-fuse on kit – AREA SPECIFIC)
• Fiber Identifier (G.657A2 Compliant for bend resistant fiber, 1 and 2k Tone detection)
• Fiber Inspection Probe includes FC (UPC/APC, SC (UPC/APC, LC, ST and D4 Tips
• Fiber Optic End Face/Port cleaning and inspection equipment
• Fiber Optical Power meter – Calibrated, Single and Multimode (Minimum nm range)
• Fiber stable light source - Calibrated, Single and Multimode (Minimum nm range) includes 1k and 2k Tone
• Fiber Visible Fault Locator (VFL) Handheld or OTDR Option
• OTDR – Minimum nm wavelengths 37/35 db Dynamic Range. (Includes File trace data, File Storage)
• Resistance tester for ground electrodes, 3-Terminal minimum
• “C” Pressure Gauge
• Digital Volt Ohm Meter
• Fiber Launch Box (Cable) - Minimum 150 meter
• Fiber Loc Splice Assembly Tool – Restoration Only, AREA SPECIFIC
• Foreign Voltage Detector (FVD)
• Gas – Nitrogen (Dry Air) Closure Flash Testing
• Kit – Fault Locate Paper/Pulp Aerial and Underground (Headset, Probe, Amplifier with Coil and Extension Poles)
• Kit - Transfer, For In-Service throws of Design Services
• Manhole package
• Blower
• Guard Rail
• Ring – Guard Assembly
• Dewatering Pump
• Guard System w/guard/lift assembly (State Requirement Specific)
• Soap and brush (leak detection)
• Gas Detectors – Confined space entry (4 Gas) MANDANTORY
• Tone Generator and Probe




Contact

x x x x Canceled/Expired Listing x x x x

listed • expires
job listing #55331 • tiny link cabl.co/eoyB